40µF · 450VAC · CBB60 Motor Run Capacitor
| Capacitance | 40 µF |
|---|---|
| Voltage | 450 VAC |
| Type | Motor Run (Polypropylene Film) |
| Body code | CBB60 |
| Terminal | Lug Terminal |
| Tolerance | ±5% |
| Frequency | 50/60 Hz |
Old part rated 370V or 440V? A 450V cap is the correct replacement for any motor-run capacitor rated 450V or below — the voltage is a ceiling, not a target; never fit a lower one. The µF must match your old capacitor (within about ±5–10%).
NZ$10.00 flat shipping — free over NZ$100. GST included.
90-day DOA guarantee — arrives dead or fails within 90 days, we replace it or refund in full, your choice. Returns & guarantees
Not sure if this fits? Use the find-my-part wizardWill this fit my machine?
9 confirmed + 1 reported models across 4 brands. Confirmed fits come from manufacturer spec sheets or capacitors we've supplied; reported fits are customer-submitted and not yet checked. Always match the µF and voltage on your own capacitor before ordering.
- FC150
- 25301Mukmova 253012530
- 6220162201SDynaflo 62201
- HM270-25HM 270-25HM270 25HM270
- PJ200PJ240P/J 200P/J 240PJ 200PJ 240
- QB2501QB2502QB3001QB3002QB 2501QB 2502QB 3001QB 3002
- VM3-17M1VM3-19M1VM3-23M1VM5-12M1VM5-14M1VM5-16M1VM10-5M1VM10-6M1VM3-17VM3-19VM3-23VM5-12VM5-14VM5-16VM10-5VM10-6VM 2.2kW
- DSF420StarFlo 420
- MQ3-45MQ3-35MQ SeriesMQ3
- CMS45E
- Always match µF (±5–10% tolerance) and voltage. Lower µF = motor won't start; higher µF = motor runs hot.
- You can substitute a higher voltage rating (e.g. 450V for a 370V slot), never lower.
- Terminal style: Lug Terminal. If your old cap had different terminals, you may need a small terminal adapter.
What you're buying
A 40µF 450VAC motor run capacitor in the CBB60 body — designed to run continuously while the motor is operating. This listing covers every terminal style — Lug Terminal, Flying Lead or Core Lead: choose yours from the Terminal dropdown above to match how your old capacitor's wires come out. The µF and voltage are identical across all of them — only the connection differs.
µF (capacitance) and voltage are the two specs that matter for fitment. µF must match the original within roughly ±5–10% — too low and the motor won't start, too high and it will run hot. Voltage must be equal or higher than the original; you can safely substitute a 450VAC unit for any motor specced at 450V or below, but never the other way around.
Commonly used for
- Compressors & air tools — typical range 25–80µF · 370/450V
- HVAC & heat pumps — typical range 5–80µF · 370/440V
- Pool & spa pumps — typical range 20–50µF · 370/450V
- Well & domestic pumps — typical range 15–40µF · 450V
Which terminal do I need?
This 40µF cap is sold as one listing with 3 terminal styles (Lug Terminal, Flying Lead or Core Lead), selectable from the dropdown above — the µF and voltage are identical across all of them, only the connection differs. Lug Terminal: 6.3mm quick-connect male tabs that take push-on female spade receptacles — no soldering, just push on. Flying Lead: two pre-attached insulated wire tails you join into a terminal block or with crimp connectors — no spade tabs. Core Lead: a central threaded stud for bracket mounting plus lead-out wires. Pick the style that matches how your old capacitor connected, or fit a spade adapter to convert between them.
Construction
- metallised polypropylene film, oval/rectangular plastic case with wire leads or spade terminals — the most common motor-run body in NZ.
- Polypropylene film, self-healing — small punctures clear without short-circuit.
- ±5% capacitance tolerance · 50/60 Hz · 70°C max ambient operating temperature.
- Mounting: Wire leads or spade terminals.
- Terminal options: Lug Terminal, Flying Lead or Core Lead — select on the page.
What not to buy this for
- Don't buy this for a motor-start application (compressor relay, pump priming) — motor-start caps have a much higher µF for short bursts and a CD60-style body. This unit is rated for continuous duty, not the high inrush of a start cap.
- Don't buy by µF alone — physical size needs to fit the housing, and the terminal style (pick Lug Terminal, Flying Lead or Core Lead to match your wiring) needs to match your existing wiring or you'll need an adapter.
New to capacitors? Our pump capacitor guide covers run vs start caps, how they fail, and how to read the µF and voltage off your old part. If you know your pump's brand and model, the pump capacitor finder maps it straight to the right replacement.
Common questions
My old capacitor is rated 370V or 440V — can I fit this 450V one?
Old part rated 370V or 440V? A 450V cap is the correct replacement for any motor-run capacitor rated 450V or below — the voltage is a ceiling, not a target; never fit a lower one. The µF must match your old capacitor (within about ±5–10%).
How closely does the 40µF capacitance need to match my old capacitor?
Match the µF to your old capacitor within about ±5–10%. Too low and the motor may not start; too high and it can run hot. Read the µF (and the voltage) printed on the side of your existing capacitor before ordering.
Which terminal option should I choose?
This listing covers 3 terminal styles (Lug Terminal, Flying Lead, Core Lead) — the µF and voltage are identical across all of them, only the connection differs. Pick the style from the Terminal dropdown that matches how your old capacitor's wires came out, or fit a spade adapter to convert between them.
Is GST included, and what does shipping cost?
Yes — the price shown includes NZ GST. Flat NZ$10 tracked shipping nationwide, free over NZ$100, and delivery is around 2 weeks.
How to install this capacitor
Step-by-step photos and a 5-minute video for the most common applications.