Ships from NZ via NZ Post, tracked · 90-day DOA guarantee
Pump capacitor fitment

Davey 25301 (Mukmova) Capacitor

The Davey 25301 (Mukmova) is a 2.20 kW single-phase transfer pump (centrifugal) commonly found in well & domestic pumps setups. Its motor runs on a 40µF 450V motor-run capacitor in a CBB60-style can: here's the exact replacement and how to confirm it.

Pump type
transfer pump (centrifugal)
Motor
2.20 kW · single-phase
Run capacitor
40µF · 450V · CBB60
Start capacitor
120µF (separate)
Tolerance
±5%
Application
Well & domestic pumps
Also sold as
25301, Mukmova 25301, 2530
Fitment source
Manufacturer-documented
Manufacturer-documented40µF · 450V

The Davey 25301 (Mukmova) transfer pump (centrifugal) uses a 40µF 450V motor-run capacitor (CBB60-style): it's the part that helps the single-phase motor start and keep running smoothly. We source this value from manufacturer / supplier documentation. Match the replacement to 40µF (about 36-44µF) at 450V or higher; the checklist below covers how to confirm it against your own capacitor.

This pump also uses a separate 120µF start capacitor. We stock CD60 start capacitors (50-500µF, 250V), but its voltage isn't in our records, so we haven't matched it to a CD60. Read the µF and voltage on your old start capacitor and ask us to check the match. It is a different part from the run capacitor above; replace whichever one has failed.

How to be sure you get the right one

  • µF must match: the 25301 (Mukmova) needs 40µF (about 36-44µF), within ±5% of the label. Too low and the motor won't start; too high and it runs hot.
  • Voltage can go up, never down: a 450V (or higher) cap is correct here; a 450V part safely replaces a 370V or 440V one. Don't fit below 450V.
  • Check the terminal + size: make sure the new cap physically fits the housing and the connections match (or use a spade adapter).
  • When in doubt, read your old cap: the printed µF and voltage on the part you're replacing is the final word.

Service parts for the Davey 25301 (Mukmova)

The seal, capacitor and bearings for this pump, on their own or as a kit. Check the old part before fitting.

Common questions - Davey 25301 (Mukmova) capacitor

What capacitor does the Davey 25301 (Mukmova) use?

A 40µF 450V motor-run capacitor (CBB60-style). Always confirm against the rating printed on your existing capacitor before ordering.

Can I fit a higher-voltage capacitor in the Davey 25301 (Mukmova)?

Yes, voltage can be equal or higher, never lower. A capacitor rated 450V or above is fine (450V is the usual choice), as long as the µF still matches (40µF).

Does the 25301 (Mukmova) need a start capacitor as well?

Yes, alongside the 40µF run capacitor it uses a separate 120µF start capacitor. Replace whichever has failed (or both if you're unsure).

Other Davey pump capacitors

Replacing the capacitor on a different Davey? These models have a confirmed or documented fitment too:

Browsing rather than replacing? All well & domestic pumps capacitors · Pump capacitor guide

Spotted a mistake, or want to confirm this fits your exact unit? Tell us. We read every message and reply within a working day.