Ships from NZ via NZ Post, tracked · 90-day DOA guarantee
Motor Bearing SetPool pump

Onga Pantera PPP1100 Bearing Set

Matched drive-end and fan-end motor bearing set to suit the Onga Pantera PPP1100 pool pump. Not made by Onga.

SKU ONG-PANTERAPPP1100-BRG
$39.95NZD
  • 6202 + 6204
  • Sealed
  • 2 bearings
Ordered inOrdered in for you, dispatched from NZ in about 2 weeks.

NZ$10.00 flat shipping, free over NZ$100. Ships from New Zealand via NZ Post, tracked. NZ addresses only.

90-day DOA guarantee: arrives faulty or fails within 90 days, we replace it or refund in full, your choice. Returns & guarantees

Not sure? Send us a photo
Motor Bearing Set$39.95

Specifications

Size6202 + 6204
SealedYes
Quantity2 bearings
SuitsOnga Pantera PPP1100
Applicationpool pump

About this part

The bearing set to suit the Onga Pantera PPP1100 is a matched pair of sealed ball bearings for the motor: one for the drive end (pump side) and one for the fan end. Replace both at the same time, because they have done the same hours and the motor has to come apart either way. Compare your old bearings with these before fitting.

Signs the Onga Pantera PPP1100 motor bearings are worn

  • A grinding, rumbling or high-pitched whine from the motor that gets louder over time.
  • The shaft feels rough, gritty or loose when turned by hand with the power off.
  • Noise that began after a leaking seal let water reach the motor.
  • The motor running hotter than it used to.

Why both bearings are changed together

The drive-end and fan-end bearings carry the same shaft and have run for the same hours, so when one is noisy the other is rarely far behind. Replacing only the loud one usually means stripping the motor down again a short time later. Fitting the pair together also lets you check the shaft and the end housings while everything is open.

Pumps that share this bearing set

The same set is listed for the Onga Leisuretime LTP1100, Onga Pantera PPP550, Onga Pantera PPP750 and Onga Pantera PPP1500. Other Onga parts are grouped on our Onga service kits page.

Fitting new bearings to the Pantera PPP1100 motor

Use a bearing puller to remove the old bearings rather than levering them off. When pressing new ones on, push only on the inner ring so the balls and races aren’t damaged, and never hammer on the outer ring. A seal leak is a common reason pump bearings fail, so if water has been getting into the motor, change the Pantera PPP1100 mechanical seal at the same time, or order the service kit to cover both.

Before you order

Check the old part before fitting: match the bearings in your old motor.

Capacitor details for this pump: Onga Pantera PPP1100 capacitor guide.

Questions

What bearings does the Onga Pantera PPP1100 motor use?

The Onga Pantera PPP1100 motor takes a matched pair of sealed ball bearings, one at the drive end and one at the fan end. This set includes both.

Do I need to replace both bearings in the Pantera PPP1100?

Yes, replace both together. They have done the same hours, and the Onga Pantera PPP1100 motor has to be stripped to reach either one.

Do the Pantera PPP750 and PPP1500 use the same bearing set as the PPP1100?

Yes. The Onga Pantera PPP550, PPP750 and PPP1500 and the Leisuretime LTP1100 are all listed with the same bearing set as the Pantera PPP1100.

Why is my Onga Pantera PPP1100 motor noisy?

A grinding or whining Onga Pantera PPP1100 motor often points to worn bearings, sometimes after a leaking seal let water in. Check the seal when you change the bearings.

Should I change the seal when I replace the Pantera PPP1100 bearings?

It is a good idea, since the motor is already apart. The Onga Pantera PPP1100 service kit includes the seal, bearings and capacitor.

What if it doesn't fit?

If you're unsure, send us a photo of your old part and the pump's label before ordering.

Other parts for the Onga Pantera PPP1100

Other pumps that use this part