Questions about your capacitor? Contact us
Pump capacitor fitment

LX WTC50 / WTC50M Circulation Pump Capacitor

The LX WTC50 / WTC50M Circulation Pump is a 0.25 kW single-phase spa circulation pump commonly found in pool & spa pumps setups. Its motor runs on a 7µF 450V motor-run capacitor in a CBB60-style can — here's the exact replacement and how to confirm it.

Pump type
spa circulation pump
Motor
0.25 kW · single-phase
Run capacitor
7µF · 450V · CBB60
Tolerance
±5%
Terminal
flying-lead
Application
Pool & spa pumps
Also sold as
WTC50, WTC50M, WTC50M-USA, WTCM50
Fitment source
Manufacturer-documented
Manufacturer-documented7µF · 450V

The LX WTC50 / WTC50M Circulation Pump spa circulation pump uses a 7µF 450V motor-run capacitor (CBB60-style) — it's the part that helps the single-phase motor start and keep running smoothly. We source this value from manufacturer / supplier documentation. Match the replacement to 7µF (about 6.3–7.7µF) at 450V or higher; the checklist below covers how to confirm it against your own capacitor.

Matching capacitor

We don't currently stock this exact value (7µF 450V). Browse the closest matches or ask us — we can usually source it.

How to be sure you get the right one

  • µF must matchthe WTC50 / WTC50M Circulation Pump needs 7µF (about 6.3–7.7µF), within roughly ±5–10%. Too low and the motor won't start; too high and it runs hot.
  • Voltage can go up, never downa 450V (or higher) cap is correct here; a 450V part safely replaces a 370V or 440V one. Don't fit below 450V.
  • Check the terminal + sizemake sure the new cap physically fits the housing and the connections match (the WTC50 / WTC50M Circulation Pump typically uses a flying-lead terminal).
  • When in doubt, read your old capthe printed µF and voltage on the part you're replacing is the final word.

Common questions — LX WTC50 / WTC50M Circulation Pump capacitor

What capacitor does the LX WTC50 / WTC50M Circulation Pump use?

A 7µF 450V motor-run capacitor (CBB60-style). Always confirm against the rating printed on your existing capacitor before ordering.

Can I fit a higher-voltage capacitor in the LX WTC50 / WTC50M Circulation Pump?

Yes — voltage can be equal or higher, never lower. A capacitor rated 450V or above is fine (450V is the usual choice), as long as the µF still matches (7µF).

Spotted a mistake, or want to confirm this fits your exact unit? Tell us — we read every message and reply within a working day.