20µF · 450VAC · CBB60 Motor Run Capacitor
- 20µF
- 450V
- CBB60
- Lug Terminal
NZ$10.00 flat shipping, free over NZ$100. Ships from New Zealand via NZ Post, tracked. NZ addresses only.
90-day DOA guarantee: arrives faulty or fails within 90 days, we replace it or refund in full, your choice. Returns & guarantees
Not sure? Send us a photoSpecifications
| Capacitance | 20µF (also written 20uF, 20 microfarad or 20 MFD) |
|---|---|
| Voltage | 450V |
| Type | Motor Run |
| Body | CBB60 |
| Terminal | Lug Terminal · Core Lead |
| Tolerance | ±5% |
| Frequency | 50/60 Hz |
Old part rated 370V or 440V? A 450V cap is the correct replacement for any motor-run capacitor rated 450V or below: the voltage is a ceiling, not a target; never fit a lower one. Match the µF on your old capacitor's label, within ±5%.
What you're buying
A 20µF 450VAC motor run capacitor in the CBB60 body, designed to run continuously while the motor is operating. This listing covers every terminal style (Lug Terminal or Core Lead): choose yours from the Terminal dropdown above to match how your old capacitor's wires come out. The µF and voltage are identical across all of them: only the connection differs.
µF (capacitance) and voltage are the two specs that matter for fitment. Match the µF on the old capacitor's label, within ±5%: too low and the motor won't start, too high and it will run hot. Voltage must be equal or higher than the original; you can safely substitute a 450VAC unit for any motor specced at 450V or below, but never the other way around.
Commonly used for
- HVAC & heat pumps: typical range 5-80µF · 370/440V
- Pool & spa pumps: typical range 15-60µF · 370/450V
- Well & domestic pumps: typical range 8-70µF · 450V
Which terminal do I need?
This 20µF cap is sold as one listing with 2 terminal styles (Lug Terminal or Core Lead), selectable from the dropdown above: the µF and voltage are identical across all of them, only the connection differs. Lug Terminal: 6.3mm quick-connect male tabs that take push-on female spade receptacles. No soldering, just push on. Core Lead: a central threaded stud for bracket mounting plus lead-out wires. Pick the style that matches how your old capacitor connected, or fit a spade adapter to convert between them.
Construction
- metallised polypropylene film, oval/rectangular plastic case with wire leads or spade terminals: the most common motor-run body in NZ.
- Polypropylene film, self-healing: small punctures clear without short-circuit.
- ±5% capacitance tolerance · 50/60 Hz · 70°C max ambient operating temperature.
- Mounting: Wire leads or spade terminals.
- Terminal options: Lug Terminal or Core Lead. Select on the page.
What not to buy this for
- Don't buy this for a motor-start application (compressor relay, pump priming). Motor-start caps usually have a much higher µF for short bursts and a CD60 body. This unit is rated for continuous duty, not the high inrush of a start cap.
- Don't buy by µF alone: physical size needs to fit the housing, and the terminal style (pick Lug Terminal or Core Lead to match your wiring) needs to match your existing wiring or you'll need an adapter.
Need a start capacitor? CD60 start capacitors, 50-500µF · how to size a CD60 start capacitor.
New to capacitors? Our pump capacitor guide covers run vs start caps, how they fail, and how to read the µF and voltage off your old part. If you know your pump's brand and model, the pump capacitor finder maps it straight to the right replacement. Before you order: how to test the old capacitor with a multimeter.
Common questions
My old capacitor is rated 370V or 440V. Can I fit this 450V one?
Old part rated 370V or 440V? A 450V cap is the correct replacement for any motor-run capacitor rated 450V or below: the voltage is a ceiling, not a target; never fit a lower one. Match the µF on your old capacitor's label, within ±5%.
How closely does the 20µF capacitance need to match my old capacitor?
Match the µF on your old capacitor's label, within ±5%. Too low and the motor may not start; too high and it can run hot. Read the µF (and the voltage) printed on the side of your existing capacitor before ordering.
Which terminal option should I choose?
This listing covers 2 terminal styles (Lug Terminal, Core Lead): the µF and voltage are identical across all of them, only the connection differs. Pick the style from the Terminal dropdown that matches how your old capacitor's wires came out, or fit a spade adapter to convert between them.
What does shipping cost, and is anything added at checkout?
Ships from New Zealand via NZ Post, tracked. Flat NZ$10 shipping nationwide, free over NZ$100. CapacitorsNZ is not GST registered, so no GST is charged or added at checkout. In NZ stock, dispatched in 1-3 working days.
Buying for a specific pump?
This 20µF capacitor is also listed under each pump model it is packed for, with that model's own fitting notes.
- AstralPool CX180 capacitor
- AstralPool CX240 capacitor
- AstralPool CX280 capacitor
- DAB Jetinox 90M capacitor
- DAB K12/200 capacitor
- DAB K30/70 capacitor
- DAB K35/40 capacitor
- Davey PowerMaster capacitor · capacitor guide
- Onga Leisuretime LTP550 capacitor · capacitor guide
- Onga Leisuretime LTP750 capacitor · capacitor guide
- Onga Pantera PPP550 capacitor · capacitor guide
- Onga Pantera PPP750 capacitor · capacitor guide
- Pedrollo PKM90 capacitor
Pump capacitor finder pages that confirm a 20µF capacitor:
- Bianco B75VAS2
- Bianco FC75
- Bianco MULTI36
- Davey 95S / 95D
- Davey CY70-75 / CY70-90
- Davey Dynajet 90
- Davey HM60-10
- Davey JY450 / JY750
- Davey SJ60-08
- Davey VM 1.1kW (VM1-17M1 / VM3-12M1 / VM5-7M1 / VM5-8M1)
- Davey XF111SS / XF211SS Transfer
- Davey XF242SS Transfer
- Davey XJ90
- Davey Dynaflo
- Davey HM90
- Davey PACR 200
- Davey PACR 300
- Davey Powerplus Series 7 (1500W Aquadrive)
- Davey StarFlo DSF150
- Davey StarFlo DSF200
- Davey StarFlo DSF300
- Davey StarFlo SF DSF1100
- Grundfos JP5
Also packed in these pump service kits: AstralPool CX180 service kit · AstralPool CX240 service kit · AstralPool CX280 service kit · DAB Jetinox 90M service kit · DAB K12/200 service kit · DAB K30/70 service kit · DAB K35/40 service kit · Davey PowerMaster service kit · Onga Leisuretime LTP550 service kit · Onga Leisuretime LTP750 service kit · Onga Pantera PPP550 service kit · Onga Pantera PPP750 service kit · Pedrollo PKM90 service kit
Wrong value? 4µF · 15µF · 16µF · 18µF · 25µF · 80µF · All CBB60 values →
How to install this capacitor
Step-by-step instructions for the most common applications.