30µF · 450VAC · CBB60 Motor Run Capacitor
- 30µF
- 450V
- CBB60
- Lug Terminal
NZ$10.00 flat shipping, free over NZ$100. Ships from New Zealand via NZ Post, tracked. NZ addresses only.
90-day DOA guarantee: arrives faulty or fails within 90 days, we replace it or refund in full, your choice. Returns & guarantees
Not sure? Send us a photoSpecifications
| Capacitance | 30µF (also written 30uF, 30 microfarad or 30 MFD) |
|---|---|
| Voltage | 450V |
| Type | Motor Run |
| Body | CBB60 |
| Terminal | Lug Terminal · Core Lead |
| Tolerance | ±5% |
| Frequency | 50/60 Hz |
Old part rated 370V or 440V? A 450V cap is the correct replacement for any motor-run capacitor rated 450V or below: the voltage is a ceiling, not a target; never fit a lower one. Match the µF on your old capacitor's label, within ±5%.
What you're buying
A 30µF 450VAC motor run capacitor in the CBB60 body, designed to run continuously while the motor is operating. This listing covers every terminal style (Lug Terminal or Core Lead): choose yours from the Terminal dropdown above to match how your old capacitor's wires come out. The µF and voltage are identical across all of them: only the connection differs.
µF (capacitance) and voltage are the two specs that matter for fitment. Match the µF on the old capacitor's label, within ±5%: too low and the motor won't start, too high and it will run hot. Voltage must be equal or higher than the original; you can safely substitute a 450VAC unit for any motor specced at 450V or below, but never the other way around.
Commonly used for
- Compressors & air tools: typical range 25-80µF · 370/450V
- HVAC & heat pumps: typical range 5-80µF · 370/440V
- Pool & spa pumps: typical range 15-60µF · 370/450V
- Well & domestic pumps: typical range 8-70µF · 450V
Which terminal do I need?
This 30µF cap is sold as one listing with 2 terminal styles (Lug Terminal or Core Lead), selectable from the dropdown above: the µF and voltage are identical across all of them, only the connection differs. Lug Terminal: 6.3mm quick-connect male tabs that take push-on female spade receptacles. No soldering, just push on. Core Lead: a central threaded stud for bracket mounting plus lead-out wires. Pick the style that matches how your old capacitor connected, or fit a spade adapter to convert between them.
Construction
- metallised polypropylene film, oval/rectangular plastic case with wire leads or spade terminals: the most common motor-run body in NZ.
- Polypropylene film, self-healing: small punctures clear without short-circuit.
- ±5% capacitance tolerance · 50/60 Hz · 70°C max ambient operating temperature.
- Mounting: Wire leads or spade terminals.
- Terminal options: Lug Terminal or Core Lead. Select on the page.
What not to buy this for
- Don't buy this for a motor-start application (compressor relay, pump priming). Motor-start caps usually have a much higher µF for short bursts and a CD60 body. This unit is rated for continuous duty, not the high inrush of a start cap.
- Don't buy by µF alone: physical size needs to fit the housing, and the terminal style (pick Lug Terminal or Core Lead to match your wiring) needs to match your existing wiring or you'll need an adapter.
Need a start capacitor? CD60 start capacitors, 50-500µF · how to size a CD60 start capacitor.
New to capacitors? Our pump capacitor guide covers run vs start caps, how they fail, and how to read the µF and voltage off your old part. If you know your pump's brand and model, the pump capacitor finder maps it straight to the right replacement. Before you order: how to test the old capacitor with a multimeter.
Common questions
My old capacitor is rated 370V or 440V. Can I fit this 450V one?
Old part rated 370V or 440V? A 450V cap is the correct replacement for any motor-run capacitor rated 450V or below: the voltage is a ceiling, not a target; never fit a lower one. Match the µF on your old capacitor's label, within ±5%.
How closely does the 30µF capacitance need to match my old capacitor?
Match the µF on your old capacitor's label, within ±5%. Too low and the motor may not start; too high and it can run hot. Read the µF (and the voltage) printed on the side of your existing capacitor before ordering.
Which terminal option should I choose?
This listing covers 2 terminal styles (Lug Terminal, Core Lead): the µF and voltage are identical across all of them, only the connection differs. Pick the style from the Terminal dropdown that matches how your old capacitor's wires came out, or fit a spade adapter to convert between them.
What does shipping cost, and is anything added at checkout?
Ships from New Zealand via NZ Post, tracked. Flat NZ$10 shipping nationwide, free over NZ$100. CapacitorsNZ is not GST registered, so no GST is charged or added at checkout. In NZ stock, dispatched in 1-3 working days.
Buying for a specific pump?
This 30µF capacitor is also listed under each pump model it is packed for, with that model's own fitting notes.
- DAB DP151 capacitor
- DAB Jet 151 capacitor
- DAB Jet 200 capacitor
- DAB K30/100 capacitor
- DAB K45/50 capacitor
- Davey PowerMaster PM450 capacitor · capacitor guide
- Davey Prime Jet 90 capacitor
- Davey Prime Jet 115 capacitor
- Davey Prime Jet 150 capacitor
- Filtermaster SB20 capacitor
Pump capacitor finder pages that confirm a 30µF capacitor:
- Bianco B120GS2
- Bianco BLC120-110S2
- Bianco PDG150M
- Bianco SB4-2/20-1.1 WF-KIT
- Bianco SB4-4/14-1.1 WF-KIT
- Davey 125S/D & 165S/D
- Davey CY70-110
- Davey Dynaflo 62101 / 60061R
- Davey HM90-13
- Davey PJ90 / PJ115 / PJ150
- Davey QB2001 / QB2002
- Davey VM 1.5kW (VM1-21/23/25M1 / VM3-15M1 / VM5-10M1 / VM10-4M1)
- Davey HM160
- Davey Hurricane M7400
- Davey StarFlo SF DSF1350
- Davey Storm 200M
- Davey Typhoon T200M
Also packed in these pump service kits: DAB DP151 service kit · DAB Jet 151 service kit · DAB Jet 200 service kit · DAB K30/100 service kit · DAB K45/50 service kit · Davey PowerMaster PM450 service kit · Davey Prime Jet 90 service kit · Davey Prime Jet 115 service kit · Davey Prime Jet 150 service kit · Filtermaster SB20 service kit
Wrong value? 4µF · 20µF · 25µF · 35µF · 40µF · 80µF · All CBB60 values →
How to install this capacitor
Step-by-step instructions for the most common applications.